| Voltage type for actuating |
AC |
| Rated control supply voltage at AC 50 Hz |
110 V |
| Rated control supply voltage at AC 60 Hz |
120 V |
| Current (Ie), max |
97 A |
| Switching frequency, max |
250 ops/h |
| Main current circuit resistance |
2.7 mOhm |
| Cross section per UL/CSA |
16 AWG |
| Rated operational current for contactor at elevator duty (UL/CSA) |
7.8 A @ 200V |
| Rated operational power for contactor at elevator duty (UL/CSA) |
5 Hp @ 575V |
| Rated isolation voltage (Ui) |
690V @ IEC |
| Rated voltage (Ue) |
690V @ AC, 50/60 Hz |
| Rated operational power for contactor at wye-delta |
5 Hp @ 230V, 60 Hz |
| Rated filament current |
12 A @ 230/240V, AC-5b |
| Power dissipation |
0.66 W @ 400V, AC-3, Ie |
| Coil terminal conductor cross section |
1…4 mm^2 @ 2 conductor |
| Rated current (enclosed) |
9.8 A @ 115V, 1-phase per UL/CSA |
| Rated power (enclosed) |
7.5 Hp @ 575V, 3-phase per UL/CSA |
| Coil consumption pick-up (avg/peak) |
14/22 W @ DC (electronic-EA) |
| General purpose current (enclosed) |
25 A per UL/CSA |
| Capacitance, max |
500 µF @ short-circuit current of 20 kA |
| Switching of low inductive loads |
32 A @ 440V, AC-7a per IEC 61095 (50 Hz) |
| Operating limits, pick-up |
(0.85...1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz |
| Switching of motor load |
9 A @ 400V, AC-7b per IEC 61095 (50 Hz) |
| Short time withstand (Icw) |
170 A for 10 s, 60 °C |
| Coil consumption, hold-in |
9.5VA/2.7 W @ 50 Hz, 60 Hz, 50/60 Hz |
| Coil consumption, pick-up |
75VA @ 50 Hz, 60 Hz, 50/60 Hz |
| Operating time |
15…30 ms @ AC closing delay |
| Total power dissipation |
DC control (electronic): 2.4 W @ 400V, AC-3, Ie |
| Operating limits, dropout |
(0.3...0.6) x Us @ 50 Hz, 60 Hz, 50/60 Hz |
| Switching of lamps |
Gas discharge lamps, open: 22.5 A @ 40 °C (104 °F), AC-5a |
| Switching of hermetically sealed cooling compressor motors |
8 A @ 690V, AC-8a (manual reset of overload release (50 Hz)) |
| Coil insulation class |
Class F per IEC 60085, UL Class 105 |
| Rating for switching AC motors |
3-poles: 7 1/2 Hp @575V (AC-2, AC-3, AC-4), 3-phase (60 Hz) |
| BS88 fuses current rating |
Type 2 (per IEC 60947-4-1): 20 A @ 415V, 65 kA available fault current |
| UL class K5 and RK5 fuses rating |
35 A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14 |
| UL class CC and CSA HRCI-MISC fuses rating |
20 A @ 100 kA available fault current per UL 508 and CSA 22.2 No. 14 |
| UL inverse-time circuit breaker |
30 A @ 600Y/347V, 25 kA available fault current per UL 508 and CSA 22.2 No. 14 |
| Rated operational current (Ie) |
9 A @ 575V, 3-phase per UL/CSA |
| Rated operational power (Pe) |
7.5 kW @ 690V, Star-Delta starting (50 Hz) |
| DIN fuses (gG, gL) current rating |
Type 2 (per IEC 60947-4-1): 25 A @ 690V, 50 kA available fault current |
| UL class J and CSA HRCI-J fuses rating |
20 A @ 100 kA available fault current per UL 508 and CSA 22.2 No. 14 |
| Switching of power transformers |
Apparent power: 9.4 kVA @ 500V, AC-6a 50 Hz (n = 30) |
| Switching of 3-phase Capacitors |
Single capacitor: 8 kVAR @ 690V, AC-6b 50 Hz, 60 °C (Inductance of leads between capacitors in parallel: min. 6 µH) |
| Switching of DC loads |
3-Poles in series: 6 A @ 220V (Shunt-wound motors starting, reverse current braking, reversing, stepping DC-3 at 60 °C) |
| Contacts |
3 power poles with internal NO or NC auxiliary contact or 4 power poles (9...23 A), Optional front-or side mounted 1-2 or 4-pole external auxiliary contact block |
| Function |
Reversing contactor |
| Rated impulse voltage withstand (Uimp) |
6 kV |
| Conventional coil type |
Yes |
| Electronic-EI coil type |
Yes |
| Rated coil frequency |
AC 50/60 Hz, DC |
| Options |
Empty |
| Optional overload relays |
Electronic or bimetallic |
| Optional accessories |
Front or side-mount auxiliary contacts, Surge suppressors, Electronic or pneumatic timers, Mechanical interlocks, Mechanical latches |
| Features |
Panel mounting or mounting on 35 mm DIN rail, AC or DC coil control, Reversible coil terminals (line or load side), Common accessories, Made of environmentally friendly materials |
| Recommended torque |
9 lb.in |
| Vibration resistance |
IEC 60068-2-6 |
| Shock resistance |
IEC 60068-2-27 |
| Coil termination |
Line side connection |
| Conductor cross section |
Main contacts, 2 conductor: 1…4 mm^2 |
| Lifespan |
Mechanical DC control: 13,000,000 ops |
| Weight |
1.27 kg (2.81 lbs) reverse @ DC |
| Type of electrical connection of main circuit |
Screw connection |
| Auxiliary contacts |
1 NO, 1 NC |
| Altitude of installation site, max |
2000 m (NN), per IEC60947-1 |
| Protection against accidental contact |
Finger-and back-of-hand proof per VDE0106, part 100 |
| Ambient temperature |
Storage: -55...80 (-67...176) |
| Protection class auxiliary contact |
IP2X |